2000 Series
e/eM Style Keypad
Installation and Programming Guide
Models 2000e and 2000eM
Specifications
Parameter Specifications
Voltage Requirements 10-30 VDC; 12-24VAC
Keypad Current
Requirements (Max)
VDC VAC
10V: 85mA
30V: 115mA
12V: 150mA
24V: 200mA
Keypad with Output
Expansion Module (2000-
8EX) Current Requirements
(Max)
VDC VAC
10V: 230mA
30V: 390mA
12V: 500mA
24V: 700mA
Note: This is total maximum current
including keypad and output module.
Relay Contact Rating 2A @ 30VDC (Main & Aux)
REX Input Normally Open Dry Contact
Door Position Switch Input Normally Closed Dry Contact
Mechanical Dimensions 4.50" H x 2.75" W x 0.60" D
Environment Indoor or Outdoor
Temperature Tolerance -31°F to 151°F (-35ºC to 66°C)
Front End Cable Type Stranded and Shielded
Front End Distance and Wire
Gauge
1000 Ft. – 18AWG; 500 Ft – 20 AWG;
250 Ft. – 22 AWG
Firmware Version
1.0x (“1” is the major version; “0” is
the minor version; “x” is a minor
version, reserved for bug fixes, which
is indicated with a letter, such as “a”.)
Technical Support
Service Company: To contact IEI’s Technical Support
department, call 1- 800-343-9502, Monday through Friday.
Questions can also be submitted through our website at
www.ieib.com
.
End User: Please contact your service company.
Keypad Operating Modes
The 2000e/2000eM keypad has three operating modes: Standalone
Mode, Secured Series Front End Mode and Wiegand Front End
Mode. Below is a brief explanation of each mode. Refer to the
programming section for details about selecting each mode.
Standalone Mode:
By default, the keypad is programmed for Standalone Mode. In
this mode, all the users and other programming options are
maintained within the keypad and no additional controller is
required. The lock and all other inputs and outputs are connected
directly to the keypad.
Secured Series Front End Mode:
In Secured Series Front End mode, an IEI Secured Series
Controller is required. The IEI Secured Series Controller
maintains the users and programming options and makes all the
access control decisions. The locking device and all inputs and
outputs are connected to the controller. The 2000e/eM keypads
were evaluated by UL, in Secured Series Front End mode, for
use only with the IEI Hub Max II and Hub MiniMax II products.
Wiegand Front End Mode:
In Wiegand Front End mode, a separate Wiegand Access Control
panel is required. When you enter a code on the keypad it is then
sent to the control panel as Wiegand card data, depending on
which format you've programmed it for. The control panel
maintains the users and programming options and makes all the
access control decisions. The locking device and all inputs and
outputs are connected to the control panel. The 2000e/eM
keypads were evaluated by UL, in Wiegand Front End mode, for
use only with the IEI Hub Max II and Hub MiniMax II products
used in conjunction with the Wiegand Interface Module.
Mounting the Keypad
The keypad is designed to be flush mounted using a standard UL
Listed single-gang electrical box. Mounting height can vary
depending on requirements. An appropriate range is typically
between 48 and 52 inches on center off the floor.
For outdoor installations, use a UL Listed weatherproof back box
and seal the wire entry locations with silicone and provide a drain
hole. For additional protection, install the provided foam gasket
between the keypad and the back box. In addition, use the anti-
oxidant grease pack for the wire harness connectors.
Document #: 6104402, Rev 2.0 Page 1 of 8
Note: For additional information about installing and
programming the 2000e/2000eM keypad please contact
IEI at 1- 800-343-9502
Vista de pagina 0
1 2 3 4 5 6 7 8

Indice de contenidos

Pagina 1 - 2000 Series

2000 Series e/eM Style Keypad Installation and Programming GuideModels 2000e and 2000eMSpecificationsParameter SpecificationsVoltage Requirements 10-3

Pagina 2 - UL Requirements

Circuit Board DiagramMain Wire Harness (P2)Pin Wire Color Description1 Red V+ (Keypad Power)2 Black V- (Keypad Power)3 White/Black Wiegand Data 0/Secu

Pagina 3

Wiring a Maglock (Fail-Safe)1. Connect the red wire (V+) to the blue wire (common), andthen connect them to the positive on the power supply.2. Connec

Pagina 4

Changing the Master CodeThe first step in setting up your keypad is to enter program modeand change the master code. The default master code is 1234.1

Pagina 5 - Programming Keypad Options

Assigning Virtual Outputs to PhysicalOutputs(Standalone Mode Only)The keypad is equipped with nineteen Virtual Outputs and twelvePhysical Outputs. Vir

Pagina 6 - Resetting the Keypad

Programming Keypad Parameters(Default settings are in bold)Command/Action Keys to Enter/DetailsChange Keypad Parameters 32 # parameter # value # **Par

Pagina 7 - Loopback

Wiring the 2000-8EX Output ModuleIf the Output Module is within 18 inches of the keypad, use the 6-conductor wire harness, supplied with the Output Mo

Pagina 8

Document #: 6104402, Rev 2.0