EXP-2000 R Electrical Connections
J1 Connections
2 - 8 to 16 VDC! Power IN (+)
1 - Ground! ! Power IN (-)
J2 Connections
8 - RS485 (+)!! RS-485 Input
7 - RS485 (-)! ! RS-485 Input
6 - +5 VDC OUT! 5 Volt Power out
5 - Relay #4! ! Analog Input #4
4 - Relay # 3 ! Analog Input #3
3 - LED I/O! ! LED Signal Output
2 - Data 1 In! ! Wiegand Data 1 Input
1 - Data 0 In! ! Wiegand Data 0 Input
J3 Connections
12 - Relay #2!! N.O. Contact
11 - Relay #2!! Common
10 - Relay #2!! N.C. Contact
9 - Relay #1! ! N.O. Contact
8 - Relay #1! ! Common
7 - Relay #1! ! N.C. Contact
6 - RS232 Output! Serial Data OUT
5 - RS232 Input! Serial Data IN
4 - Ground! ! Wiegand/RS232 Ground
3 - Aux in! ! Digital Input
2 -! ! ! Not used
1 - ! ! ! Not used
DIP Switch Address Settings
ADDRESS! ! SWITCH!
!!!12345678
1! ! ! 00000001
2! ! ! 00000010
3! ! ! 00000011
4! ! ! 00000100
5! ! ! 00000101
6! ! ! 00000110
7! ! ! 00000111
8! ! ! 00001000
9! ! ! 00001001
10! ! ! 00001010
11! ! ! 00001011
12! ! ! 00001100
13! ! ! 00001101
14! ! ! 00001110
15! ! ! 00001111!
16! ! ! 00010000
1
2
3
4
5
6
7
8
On
Off
Address settings for the EXP-2000
Cypress Suprex® systems will support different numbers
of additional EXP-2000 units depending upon the model
number. Refer to the specific documents for the
SPX-7400, SPX-5600, or SPX-7200 for maximum ratings.
Note:
To operate as a "Remote" unit, DIP Switch #2 must be Off.
*
J1
J2
J3
2- 8 to 16 VDC In
1- Ground
.
12- R2 N.O.
11- R2 Com
10- R2 N.C
9- R1 N.O.
8- R1 Com
7- R1 N.C.
6-RS232 output
5-RS232 Input
4-Ground
3- Aux in
2- Not used
1 - Not used
8-RS485 (+)
7-RS485 (-)
6-+5 VDC Out
5- R4 in
4- R3 in
3-LED out
2-Data 1 in
1-Data 0 in