To preventpossible OVERHEATING of the end panel or light socket:
• Use ONLY A19 incandescent(100Wmaximum) or compact fluorescent (26Wmaximum) light
bulbs.
• DO NOT use incandescentbulbs larger than 100W.
• DO NOT use compact fluorescent lightbulbs larger than 26W (100W equivalent).
• DO NOT use halogen bulbs.
• DO NOT use short neck or specialty light bulbs.
6.1 Pull on the top center of the lightlensand rotate the
lightlens down.
6.2 Insert an A19 incandescent (100W maximum) or
compact fluorescent (26W, 100Wequivalent)light
bulb into the light socket.
NOTE: Do not use halogen, short neck, or specialty light
bulbs as these may overheat the end panel or light socket.
Do not use LED bulbs as they may reduce the range or
performance of your remote control(s).
6.3 Rotate the lensup to close.
7 Attach the emergency release rope and handle
To preventpossible SERIOUS INJURY or DEATHfrom a falling garage door:
• Ifpossible, use emergencyrelease handle to disengage trolley ONLY when garage door is
CLOSED. Weak or broken springs or unbalanced door could result in an open door falling
rapidly and/or unexpectedly.
• NEVER use emergency release handle unlessgarage doorwayisclear of persons and
obstructions.
• NEVER use handle to pull door open or closed.Ifrope knotbecomes untied,you could fall.
7.1 Insert one end of the emergency release rope
through the handle. Make sure that“NOTICE” is
rightside up. Tie a knot at least1 inch (2.5 cm) from
the end of the emergency release rope.
7.2 Insert the other end ofthe emergency release rope
through the hole in the trolley release arm. Mount
the emergency release within reach,but at least 6
feet(1.83 m) above the floor, avoiding contact with
vehiclesto prevent accidental release and secure
with a knot.
NOTE: If it is necessary to cut the emergency release rope,
seal the cut end with a match or lighter to prevent
unraveling. Ensure the emergency release rope and
handle are above the top of all vehicles to avoid
entanglement.