Controlled-products-systems-group SLIDESMART DC 10F Manual de usuario Pagina 101

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 148
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 100
Installing a MagLock or Solenoid Lock
Revision D Reference 6-3
Installing a Lock for 12VDC or 24VDC Systems
To install a lock for 12VDC or 24VDC
systems, take the following steps:
1. Connect a wire between COM on
USER 1 RELAY and a COM terminal
on the Smart DC Controller board. See
Figure 6-2.
2. Connect the power lead from the lock
to the appropriate power spade
(+24VDC or +12VDC)
3. Connect the common wire from the
lock to NC on USER 1 RELAY.
Note:Connect to NO on USER 1
RELAY if installing a Solenoid lock.
4. Set the User Relay function in the
Installer Menu to RL1 - 6. Refer to
Setting the User Relay Function in the
Installer Menu.
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
RADIO
CLOSE
OPEN
OPEN
PARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
U
SE
R
2
C
OM
N
O
D
C
USER 1 RELAY
NO
NC
COM
24VDC
24VDC
24VAC
24VAC
12VDC
12VDC
Aach the power wire from the lock
to the appropriate power spade.
Connect COM on board
to COM on USER 1 RELAY.
Connect the COM wire from
the lock.
A Solenoid lock aaches to NO.
A MagLock aaches to NC.
Figure 6-2.
1
2
3
Vista de pagina 100
1 2 ... 96 97 98 99 100 101 102 103 104 105 106 ... 147 148

Comentarios a estos manuales

Sin comentarios